Make A Decision Now! Update Your Production Line Or Not?
Inquiry is free, what about checking the price first?

| Parameter | Value | Explanation |
|---|---|---|
| Nominal size | 25 mm | Defines the size of the linear bearing block, ensuring compatibility with 25 mm guide rails. |
| Format | FLS – flange, long, standard height | Flanged design with extended length for increased stability and load capacity. |
| Material | Carbon steel | Unalloyed steel CS provides durability and strength for heavy-duty applications. |
| Preload class | C1 – Low preload | Minimizes internal forces, reducing friction and wear during operation. |
| Accuracy class | H – Highly accurate | Ensures precise motion control, critical for high-precision applications. |
| Seal | SS – Standard seal | Protects against dust and contaminants, extending component lifespan. |
| Width of runner block | 70 mm (2.76 in) | Provides a stable base for mounting and load distribution. |
| Length of runner block | 107.9 mm (4.25 in) | Extended length enhances rigidity and load-bearing capacity. |
| Height of runner block | 29.9 mm (1.18 in) | Compact height suits space-constrained installations. |
| Height with guide rail | 36 mm (1.42 in) | Total height including rail, critical for system design. |
| Dynamic load capacity C100 | 37300 N | Maximum load the block can handle for 100,000 m travel (per DIN ISO 14728-1). |
| Dynamic load capacity C50 | 47000 N | Load capacity for 50,000 m travel, offering higher performance for shorter distances. |
| Static load capacity C0 | 52500 N | Maximum static load the block can withstand without deformation. |
| Maximum acceleration amax | 500 m/s² (1640 ft/s²) | Supports high-speed applications with rapid acceleration. |
| Maximum permissible linear speed vmax | 5 m/s (16.4 ft/s) | Ensures reliable performance at high speeds. |
| Friction coefficient μ | 0.002–0.003 | Low friction enhances efficiency and reduces wear. |
| Weight | 0.9 kg (1.98 lbs) | Lightweight design simplifies installation and reduces system load. |
| Permissible ambient temperature | -10 °C to +80 °C (14 °F to 176 °F), 100 °C (212 °F) for short periods | Operates reliably in a wide range of industrial environments. |
| Dynamic torsional moment load capacity Mt100 | 530 Nm | Resists twisting forces during 100,000 m travel, ensuring stability. |
| Static torsional moment load capacity Mt0 | 750 Nm | Handles high static twisting forces without compromising performance. |
| Dynamic longitudinal moment load capacity ML100 | 530 Nm | Supports longitudinal forces during 100,000 m travel, enhancing durability. |
| Static longitudinal moment load capacity ML0 | 740 Nm | Ensures stability under static longitudinal loads. |
| Version | Ball rail system |
| Nominal size [mm] | 25 |
| Format | FLS – flange, long, standard height |
| Model | High-precision ball runner block |
| Material | Carbon steel |
| Preload class | C1 – Low preload |
| Accuracy class | H – Highly accurate |
| Seal | SS – Standard seal |
| Ball chain | Without ball chain (standard) |
| Self-aligning for compensation of misalignments | Without self-alignment |
| Width of runner block [mm] | 70 |
| Length of runner block [mm] | 107.9 |
| Height of runner block [mm] | 29.9 |
| Height runner block with guide rail [mm] | 36 |
| Lubrication | With initial lubrication and preservation |
| Dynamic load capacity C100 [N] | 37300 |
| Note: dynamic load capacity C100 | Dynamic load capacities and load moments are based on a stroke travel of 100,000 m according to DIN ISO 14728-1. |
| Maximum acceleration rate amax [m/s²] | 500 |
| Note: Max. acceleration amax | If Fcomb◡> 2.8 • Fpr : amax = 50 m/s2 |
| Maximum permissible linear speed vmax [m/s] | 5 |
| Permissible ambient temperature (min. … max.) | -10 °C … +80 °C |
| Note: permissible ambient temperature (min. … max.) | 100 °C admissible for short time. For operation at negative temperatures, please consult us. |
| Friction coefficient μ | 0.002 … 0.003 |
| Note: friction coefficient μ | Without friction of seal |
| Weight [kg] | 0.9 |
| Dynamic load capacity C50 [N] | 47000 |
| Note: dynamic load capacity C50 | Dynamic load capacity and load moments based on a travel of 50,000 m. |
| Static load capacity C0 [N] | 52500 |
| Dynamic torsional moment load capacity Mt50 [Nm] | 670 |
| Note: Dynamic torsional moment load capacity Mt50 | Dynamic load capacity and load moments based on a travel of 50,000 m. |
| Dynamic torsional moment load capacity Mt100 [Nm] | 530 |
| Note: Dynamic torsional moment load capacity Mt100 | Dynamic load capacities and load moments are based on a stroke travel of 100,000 m according to DIN ISO 14728-1. |
| Static torsional moment load capacity Mt0 [Nm] | 750 |
| Dynamic longitudinal moment load capacity ML50 [Nm] | 670 |
| Note: Dynamic longitudinal moment load capacity ML50 | Dynamic load capacity and load moments based on a travel of 50,000 m. |
| Dynamic longitudinal moment load capacity ML100 [Nm] | 530 |
| Note: Dynamic longitudinal moment load capacity ML100 | Dynamic load capacities and load moments are based on a stroke travel of 100,000 m according to DIN ISO 14728-1. |
| Static longitudinal moment load capacity ML0 [Nm] | 740 |
| Pitch T guide rail [mm] | 60 |
| Dimension A (profiled rail systems) [mm] | 70 |
| Dimension A1 (profiled rail systems) [mm] | 35 |
| Dimension A2 (profiled rail systems) [mm] | 23 |
| Dimension A3 (profiled rail systems) [mm] | 23.5 |
| Dimension B (profiled rail systems) [mm] | 107.9 |
| Dimension B tolerance (profiled rail systems) [mm] | +0.5 |
| Dimension B1 [mm] | 79.5 |
| Dimension E1 [mm] | 57 |
| Dimension E2 (profiled rail systems) [mm] | 45 |
| Dimension E3 (profiled rail systems) [mm] | 40 |
| Dimension E8 (profiled rail systems) [mm] | 38.3 |
| Dimension E9 (profiled rail systems) [mm] | 11.5 |
| Dimension H [mm] | 36 |
| Dimension H1 (profiled rail systems) [mm] | 29.9 |
| Dimension H2 with cover strip (profiled rail systems) [mm] | 24.45 |
| Dimension H2 without cover strip (profiled rail systems) [mm] | 24.25 |
| Dimension K1 (profiled rail systems) [mm] | 23.3 |
| Dimension K2 (profiled rail systems) [mm] | 24.45 |
| Dimension K3 (profiled rail systems) [mm] | 5.5 |
| Dimension K4 (profiled rail systems) [mm] | 5.5 |
| Dimension N1 (profiled rail systems) [mm] | 9.3 |
| Dimension N2 (profiled rail systems) [mm] | 7 |
| Dimension N6 (profiled rail systems) [mm] | 15.2 |
| Dimension N6 tolerance (profiled rail systems) [mm] | ±0.5 |
| Dimension S1 (profiled rail systems) [mm] | 6.7 |
| Dimension S2 (profiled rail systems) | M8 |
| Dimension S5 (profiled rail system) [mm] | 7 |
| Dimension S9 | M3x5 mm |
| Dimension S9 thread diameter (profiled rail systems) | M3 |
| Dimension S9 lead [mm] | 5 |
| Dimension T1 min [mm] | 13 |
| Dimension V1 [mm] | 7.5 |