Parameter | Value | Explanation |
---|---|---|
Nominal Size | 30 mm (1.181 inches) | Defines the size of the linear bearing block, critical for rail compatibility. |
Width of Runner Block | 90 mm (3.543 inches) | Width dimension ensures stability during operation. |
Length of Runner Block | 97.7 mm (3.846 inches) | Length affects load distribution and mounting requirements. |
Height of Runner Block | 35.35 mm (1.392 inches) | Height impacts the overall system profile and clearance. |
Dynamic Load Capacity C100 | 34800 N | Maximum load the block can handle during 100,000 m travel (per DIN ISO 14728-1). |
Static Load Capacity C0 | 44700 N | Maximum static load the block can withstand without deformation. |
Dynamic Torsional Moment Load Capacity Mt100 | 600 Nm | Resistance to twisting forces during dynamic operation. |
Static Torsional Moment Load Capacity Mt0 | 780 Nm | Resistance to twisting forces when stationary. |
Dynamic Longitudinal Moment Load Capacity ML100 | 420 Nm | Resistance to longitudinal moments during motion. |
Static Longitudinal Moment Load Capacity ML0 | 540 Nm | Resistance to longitudinal moments when stationary. |
Maximum Acceleration amax | 500 m/s² | Maximum acceleration under standard conditions; reduces to 50 m/s² if combined force exceeds 2.8 times preload. |
Maximum Permissible Linear Speed vmax | 5 m/s | Maximum speed for safe operation. |
Friction Coefficient μ | 0.002 … 0.003 | Low friction ensures smooth motion and energy efficiency. |
Permissible Ambient Temperature | 0 °C to +80 °C (32 °F to 176 °F); 100 °C (212 °F) for short periods | Operating temperature range; consult Rexroth for negative temperatures. |
Weight | 1.1 kg (2.425 lbs) | Weight impacts system design and load calculations. |
Product attributes | |
---|---|
Version | Ball rail system |
Nominal size [mm] | 30 |
Format | FNS – flange, normal, standard height |
Model | High-precision ball runner block |
Material (profiled rail systems) | Carbon steel |
Preload class | C2 – Medium preload |
Accuracy class | H – Highly accurate |
Seal | SS – Standard seal |
Ball chain | With ball chain |
Self-aligning for compensation of misalignments | Without self-alignment |
Width of runner block [mm] | 90 |
Length of runner block [mm] | 97.7 |
Height of runner block [mm] | 35.35 |
Height runner block with guide rail [mm] | 42 |
Lubrication | With initial lubrication and preservation |
Dynamic load capacity C100 [N] | 34800 |
Note: dynamic load capacity C100 | Dynamic load capacities and load moments are based on a stroke travel of 100,000 m according to DIN ISO 14728-1. |
Maximum acceleration rate amax [m/s²] | 500 |
Note: Max. acceleration amax | If Fcomb◡> 2.8 • Fpr : amax = 50 m/s2 |
Maximum permissible linear speed vmax [m/s] | 5 |
Permissible ambient temperature (min. … max.) | 0 °C … +80 °C |
Note: permissible ambient temperature (min. … max.) | 100 °C admissible for short time. For operation at negative temperatures, please consult us. |
Friction coefficient μ | 0.002 … 0.003 |
Note: friction coefficient μ | Without friction of seal |
Weight [kg] | 1.1 |
Dynamic load capacity C50 [N] | 43800 |
Note: dynamic load capacity C50 | Dynamic load capacity and load moments based on a travel of 50,000 m. |
Static load capacity C0 [N] | 44700 |
Dynamic torsional moment load capacity Mt50 [Nm] | 760 |
Note: Dynamic torsional moment load capacity Mt50 | Dynamic load capacity and load moments based on a travel of 50,000 m. |
Dynamic torsional moment load capacity Mt100 [Nm] | 600 |
Note: Dynamic torsional moment load capacity Mt100 | Dynamic load capacities and load moments are based on a stroke travel of 100,000 m according to DIN ISO 14728-1. |
Static torsional moment load capacity Mt0 [Nm] | 780 |
Dynamic longitudinal moment load capacity ML50 [Nm] | 530 |
Note: Dynamic longitudinal moment load capacity ML50 | Dynamic load capacity and load moments based on a travel of 50,000 m. |
Dynamic longitudinal moment load capacity ML100 [Nm] | 420 |
Note: Dynamic longitudinal moment load capacity ML100 | Dynamic load capacities and load moments are based on a stroke travel of 100,000 m according to DIN ISO 14728-1. |
Static longitudinal moment load capacity ML0 [Nm] | 540 |
Pitch T guide rail [mm] | 80 |
Dimension A (profiled rail systems) [mm] | 90 |
Dimension A1 (profiled rail systems) [mm] | 45 |
Dimension A2 (profiled rail systems) [mm] | 28 |
Dimension A3 (profiled rail systems) [mm] | 31 |
Dimension B (profiled rail systems) [mm] | 97.7 |
Dimension B tolerance (profiled rail systems) [mm] | +0.5 |
Dimension B1 [mm] | 67.4 |
Dimension E1 [mm] | 72 |
Dimension E2 (profiled rail systems) [mm] | 52 |
Dimension E3 (profiled rail systems) [mm] | 44 |
Dimension E8 (profiled rail systems) [mm] | 48.4 |
Dimension E9 (profiled rail systems) [mm] | 14.6 |
Dimension H [mm] | 42 |
Dimension H1 (profiled rail systems) [mm] | 35.35 |
Dimension H2 with cover strip (profiled rail systems) [mm] | 28.55 |
Dimension H2 without cover strip (profiled rail systems) [mm] | 28.35 |
Dimension K1 (profiled rail systems) [mm] | 14 |
Dimension K2 (profiled rail systems) [mm] | 15.7 |
Dimension K3 (profiled rail systems) [mm] | 6.05 |
Dimension K4 (profiled rail systems) [mm] | 6.05 |
Dimension N1 (profiled rail systems) [mm] | 11 |
Dimension N2 (profiled rail systems) [mm] | 7.9 |
Dimension N6 (profiled rail systems) [mm] | 17 |
Dimension N6 tolerance (profiled rail systems) [mm] | ±0.5 |
Dimension S1 (profiled rail systems) [mm] | 8.5 |
Dimension S2 (profiled rail systems) | M10 |
Dimension S5 (profiled rail system) [mm] | 9 |
Dimension S9 | M3x5 mm |
Dimension S9 thread diameter (profiled rail systems) | M3 |
Dimension S9 lead [mm] | 5 |
Dimension T1 min [mm] | 16 |
Dimension V1 [mm] | 7 |